Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 9771, 2024 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684823

RESUMEN

Transpulmonary pressure can be estimated using esophageal balloon (EB) catheters, which come in a variety of manufacturing configurations. We assessed the performance of novel polyurethane EB designs, Aspisafe NG and NG+, against existing alternatives. We created a biomechanical model of the chest cavity using a plastic chamber and an ex-vivo porcine esophagus. The chamber was pressurized (- 20 and + 20 cmH2O) to simulate pleural pressures. We conducted tests with various EB inflation volumes and measured transesophageal pressure (TEP). TEP measurement was defined as accurate when the difference between pressure within the EB and chamber was 0 ± 1 cmH2O. We computed the minimal (Vaccuracy-min) and maximal (Vaccuracy-max) EB inflation volumes of accuracy. Inflation volumes were further validated using a surrogate method derived by the clinically validated positive pressure occlusion test (PPOT). When the esophageal balloons were filled with inflation volumes within the range provided by the manufacturers, the accuracy of TEP measurements was marginal. Our tests found median Vaccuracy-min across EB of 0.00-0.50 mL (p = 0.130), whereas Vaccuracy-max ranged 0.50-2.25 mL (p = 0.002). Post PPOT validation, median TEP was - 0.4 cmH2O (- 1.5 to 0.3) (p < 0.001 among catheters). The Aspisafe NG and NG+ were accurate in 81.7% and 77.8% of the measurements, respectively. We characterized two new EBs, which demonstrated good benchtop accuracy in TEP measurements. However, accuracy was notably influenced by the precise selection of EB inflation volumes.


Asunto(s)
Catéteres , Esófago , Presión , Cavidad Torácica , Animales , Esófago/fisiología , Porcinos , Fenómenos Biomecánicos , Poliuretanos/química , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación
3.
Sci Rep ; 14(1): 2162, 2024 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-38272980

RESUMEN

Mortality and morbidity of Acute Respiratory Distress Syndrome (ARDS) are largely unaltered. A possible new approach to treatment of ARDS is offered by the discovery of inflammatory subphenotypes. In an ovine model of ARDS phenotypes, matching key features of the human subphenotypes, we provide an imaging characterization using computer tomography (CT). Nine animals were randomized into (a) OA (oleic acid, hypoinflammatory; n = 5) and (b) OA-LPS (oleic acid and lipopolysaccharides, hyperinflammatory; n = 4). 48 h after ARDS induction and anti-inflammatory treatment, CT scans were performed at high (H) and then low (L) airway pressure. After CT, the animals were euthanized and lung tissue was collected. OA-LPS showed a higher air fraction and OA a higher tissue fraction, resulting in more normally aerated lungs in OA-LPS in contrast to more non-aerated lung in OA. The change in lung and air volume between H and L was more accentuated in OA-LPS, indicating a higher recruitment potential. Strain was higher in OA, indicating a higher level of lung damage, while the amount of lung edema and histological lung injury were largely comparable. Anti-inflammatory treatment might be beneficial in terms of overall ventilated lung portion and recruitment potential, especially in the OA-LPS group.


Asunto(s)
Lipopolisacáridos , Síndrome de Dificultad Respiratoria , Animales , Antiinflamatorios/farmacología , Antiinflamatorios/uso terapéutico , Pulmón/patología , Ácido Oléico/farmacología , Fenotipo , Síndrome de Dificultad Respiratoria/patología , Ovinos , Oveja Doméstica , Tomografía
4.
Eur J Clin Invest ; 54(2): e14106, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37822060

RESUMEN

BACKGROUND: Left ventricular stroke work index (LVSWI) and afterload-related cardiac performance (ACP) consider left ventricular (LV) afterload and could be better prognosticators in septic cardiomyopathy. However, their invasive nature prevents their routine clinical applications. This study aimed to investigate (1) whether a proposed speckle-tracking echocardiography parameter, Pressure-Strain Product (PSP), can non-invasively predict catheter-based LVSWI, ACP and serum lactate in an ovine model of septic cardiomyopathy; and (2) whether PSP can distinguish the sub-phenotypes of acute respiratory distress syndrome (ARDS) with or without sepsis-like conditions. METHODS: Sixteen sheep with ARDS were randomly assigned to either (1) sepsis-like (n = 8) or (2) non-sepsis-like (n = 8) group. Each ARDS and sepsis-like condition was induced by intravenous infusion of oleic acid and lipopolysaccharide, respectively. Pulmonary artery catheter-based LVSWI (the product of stroke work index, mean arterial pressure and .0136), ACP (the percentage of cardiac output measured to cardiac output predicted as normal) and serum lactate were measured simultaneously with transthoracic echocardiography. Two PSP indices were calculated by multiplying the mean arterial blood pressure and either global circumferential strain (PSPcirc) or radial strain (PSPrad). RESULTS: PSPcirc showed a significant correlation with LVSWI (r2 = .66, p < .001) and ACP (r2 = .82, p < .001) in the sepsis-like group. Although PSP could not distinguish subphenotypes, PSPcirc predicted LVSWI (AUC .86) and ACP (AUC .88), and PSPrad predicted serum lactate (AUC .75) better than LV ejection fraction, global circumferential and radial strain. CONCLUSIONS: A novel PSP has the potential to non-invasively predict catheter-based LVSWI and ACP, and was associated with serum lactate in septic cardiomyopathy.


Asunto(s)
Cardiomiopatías , Síndrome de Dificultad Respiratoria , Sepsis , Accidente Cerebrovascular , Disfunción Ventricular Izquierda , Animales , Ovinos , Ecocardiografía , Volumen Sistólico , Función Ventricular Izquierda , Lactatos , Disfunción Ventricular Izquierda/diagnóstico por imagen
5.
Sci Rep ; 13(1): 17986, 2023 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-37863994

RESUMEN

Whilst the presence of 2 subphenotypes among the heterogenous Acute Respiratory Distress Syndrome (ARDS) population is becoming clinically accepted, subphenotype-specific treatment efficacy has yet to be prospectively tested. We investigated anti-inflammatory treatment in different ARDS models in sheep, previously shown similarities to human ARDS subphenotypes, in a preclinical, randomized, blinded study. Thirty anesthetized sheep were studied up to 48 h and randomized into: (a) OA: oleic acid (n = 15) and (b) OA-LPS: oleic acid and subsequent lipopolysaccharide (n = 15) to achieve a PaO2/FiO2 ratio of < 150 mmHg. Then, animals were randomly allocated to receive treatment with methylprednisolone or erythromycin or none. Assessed outcomes were oxygenation, pulmonary mechanics, hemodynamics and survival. All animals reached ARDS. Treatment with methylprednisolone, but not erythromycin, provided the highest therapeutic benefit in Ph2 animals, leading to a significant increase in PaO2/FiO2 ratio by reducing pulmonary edema, dead space ventilation and shunt fraction. Animals treated with methylprednisolone displayed a higher survival up to 48 h than all others. In animals treated with erythromycin, there was no treatment benefit regarding assessed physiological parameters and survival in both phenotypes. Treatment with methylprednisolone improves oxygenation and survival, more so in ovine phenotype 2 which resembles the human hyperinflammatory subphenotype.


Asunto(s)
Antiinflamatorios , Ácido Oléico , Síndrome de Dificultad Respiratoria , Animales , Antiinflamatorios/farmacología , Antiinflamatorios/uso terapéutico , Eritromicina/uso terapéutico , Metilprednisolona/farmacología , Metilprednisolona/uso terapéutico , Ácido Oléico/uso terapéutico , Respiración , Ovinos , Distribución Aleatoria , Modelos Animales de Enfermedad
6.
J Heart Lung Transplant ; 42(8): 1015-1029, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37031869

RESUMEN

BACKGROUND: The global shortage of donor hearts available for transplantation is a major problem for the treatment of end-stage heart failure. The ischemic time for donor hearts using traditional preservation by standard static cold storage (SCS) is limited to approximately 4 hours, beyond which the risk for primary graft dysfunction (PGD) significantly increases. Hypothermic machine perfusion (HMP) of donor hearts has been proposed to safely extend ischemic time without increasing the risk of PGD. METHODS: Using our sheep model of 24 hours brain death (BD) followed by orthotopic heart transplantation (HTx), we examined post-transplant outcomes in recipients following donor heart preservation by HMP for 8 hours, compared to donor heart preservation for 2 hours by either SCS or HMP. RESULTS: Following HTx, all HMP recipients (both 2 hours and 8 hours groups) survived to the end of the study (6 hours after transplantation and successful weaning from cardiopulmonary bypass), required less vasoactive support for hemodynamic stability, and exhibited superior metabolic, fluid status and inflammatory profiles compared to SCS recipients. Contractile function and cardiac damage (troponin I release and histological assessment) was comparable between groups. CONCLUSIONS: Overall, compared to current clinical SCS, recipient outcomes following transplantation are not adversely impacted by extending HMP to 8 hours. These results have important implications for clinical transplantation where longer ischemic times may be required (e.g., complex surgical cases, transport across long distances). Additionally, HMP may allow safe preservation of "marginal" donor hearts that are more susceptible to myocardial injury and facilitate increased utilization of these hearts for transplantation.


Asunto(s)
Trasplante de Corazón , Animales , Ovinos , Humanos , Preservación de Órganos/métodos , Donantes de Tejidos , Perfusión/métodos , Corazón
7.
Sci Rep ; 13(1): 4002, 2023 03 10.
Artículo en Inglés | MEDLINE | ID: mdl-36899029

RESUMEN

Differential hypoxaemia (DH) is common in patients supported by femoral veno-arterial extracorporeal membrane oxygenation (V-A ECMO) and can cause cerebral hypoxaemia. To date, no models have studied the direct impact of flow on cerebral damage. We investigated the impact of V-A ECMO flow on brain injury in an ovine model of DH. After inducing severe cardiorespiratory failure and providing ECMO support, we randomised six sheep into two groups: low flow (LF) in which ECMO was set at 2.5 L min-1 ensuring that the brain was entirely perfused by the native heart and lungs, and high flow (HF) in which ECMO was set at 4.5 L min-1 ensuring that the brain was at least partially perfused by ECMO. We used invasive (oxygenation tension-PbTO2, and cerebral microdialysis) and non-invasive (near infrared spectroscopy-NIRS) neuromonitoring, and euthanised animals after five hours for histological analysis. Cerebral oxygenation was significantly improved in the HF group as shown by higher PbTO2 levels (+ 215% vs - 58%, p = 0.043) and NIRS (67 ± 5% vs 49 ± 4%, p = 0.003). The HF group showed significantly less severe brain injury than the LF group in terms of neuronal shrinkage, congestion and perivascular oedema (p < 0.0001). Cerebral microdialysis values in the LF group all reached the pathological thresholds, even though no statistical difference was found between the two groups. Differential hypoxaemia can lead to cerebral damage after only a few hours and mandates a thorough neuromonitoring of patients. An increase in ECMO flow was an effective strategy to reduce such damages.


Asunto(s)
Lesiones Encefálicas , Oxigenación por Membrana Extracorpórea , Animales , Lesiones Encefálicas/complicaciones , Oxigenación por Membrana Extracorpórea/efectos adversos , Hipoxia/complicaciones , Modelos Teóricos , Ovinos , Choque Cardiogénico/etiología
8.
J Vasc Access ; : 11297298221127760, 2022 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-36281219

RESUMEN

BACKGROUND: Peripheral intravenous catheters (PIVCs) are the most commonly used invasive medical device, yet despite best efforts by end-users, PIVCs experience unacceptably high early failure rates. We aimed to design a new PIVC that reduces the early failure rate of in-dwelling PIVCs and we conducted preliminary tests to assess its efficacy and safety in a porcine model of intravenous access. METHODS: We used computer-aided design and simulation to create a PIVC with a ramped tip geometry, which directs the infused fluid away from the vein wall; we called the design the FloRamp™. We created FloRamp prototypes (test device) and tested them against a market-leading device (BD Insyte™; control device) in a highly-controlled setting with five insertion sites per device in four pigs. We measured resistance to infusion and visual infusion phlebitis (VIP) every 6 h and terminated the experiment at 48 h. Veins were harvested for histology and seven pathological markers were assessed. RESULTS: Computer simulations showed that the optimum FloRamp tip reduced maximum endothelial shear stress by 60%, from 12.7 Pa to 5.1 Pa, compared to a typical PIVC tip and improved the infusion dynamics of saline in the blood stream. In the animal study, we found that 2/5 of the control devices were occluded after 24 h, whereas all test devices remained patent and functional. The FloRamp created less resistance to infusion (0.73 ± 0.81 vs 0.47 ± 0.50, p = 0.06) and lower VIP scores (0.60 ± 0.93 vs 0.31 ± 0.70, p = 0.09) than the control device, although neither findings were significantly different. Histopathology revealed that 5/7 of the assessed markers were lower in veins with the FloRamp. CONCLUSIONS: Herein we report preliminary assessment of a novel PIVC design, which could be advantageous in clinical settings through decreased device occlusion and reduced early failure rates.

9.
Metabolites ; 12(7)2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35888779

RESUMEN

Despite decades of comprehensive research, Acute Respiratory Distress Syndrome (ARDS) remains a disease with high mortality and morbidity worldwide. The discovery of inflammatory subphenotypes in human ARDS provides a new approach to study the disease. In two different ovine ARDS lung injury models, one induced by additional endotoxin infusion (phenotype 2), mimicking some key features as described in the human hyperinflammatory group, we aim to describe protein expression among the two different ovine models. Nine animals on mechanical ventilation were included in this study and were randomized into (a) phenotype 1, n = 5 (Ph1) and (b) phenotype 2, n = 4 (Ph2). Plasma was collected at baseline, 2, 6, 12, and 24 h. After protein extraction, data-independent SWATH-MS was applied to inspect protein abundance at baseline, 2, 6, 12, and 24 h. Cluster analysis revealed protein patterns emerging over the study observation time, more pronounced by the factor of time than different injury models of ARDS. A protein signature consisting of 33 proteins differentiated among Ph1/2 with high diagnostic accuracy. Applying network analysis, proteins involved in the inflammatory and defense response, complement and coagulation cascade, oxygen binding, and regulation of lipid metabolism were activated over time. Five proteins, namely LUM, CA2, KNG1, AGT, and IGJ, were more expressed in Ph2.

10.
J Mater Chem B ; 10(26): 4974-4983, 2022 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-35695541

RESUMEN

Extracorporeal membrane oxygenation (ECMO), a critical life-sustaining tool, faces significant challenges for the maintenance of normal haemostasis due to the large volume of circulating blood continuously in contact with artificial surfaces, hyperoxia and excessive shear stresses of the extracorporeal circuit. From a biomaterials perspective, it has been hypothesised that drug eluting coatings composed of haemocompatible hydrogels loaded with an anticoagulant drug could potentially enhance the haemocompatibility of the circuit. Poly(ethylene glycol) (PEG) has been well established as a biocompatible and anti-fouling material with wide biomedical application. Unfractionated heparin is the most commonly used anticoagulant for ECMO. In the present study, the feasibility of using heparin-loaded PEG-based hydrogels as anti-thrombogenic surface coatings for ECMO was investigated. The hydrogels were synthesised by photopolymerisation using poly(ethylene glycol) diacrylate (PEGDA) as the crosslinking monomer and poly(ethylene glycol) methacrylate (PEGMA) as the hydrophilic monomer, with heparin loaded into the pre-gel solution. Factors which could affect the release of heparin were investigated, including the ratio of PEGDA/PEGMA, water content, loading level of heparin and the flow of fluid past the hydrogel. Our results showed that increased crosslinker content and decreased water content led to slower heparin release. The hydrogels with water contents of 60 wt% and 70 wt% could achieve a sustained heparin release by adjusting the ratio of PEGDA/PEGMA. The anticoagulation efficacy of the released heparin was evaluated by measuring the activated clotting time of whole blood. The hydrogels with desirable heparin release profiles were prepared onto poly(4-methyl-1-pentene) (PMP) films with the same chemical composition as the PMP ECMO membranes. The coatings showed sustained heparin release with a cumulative release of 70-80% after 7 days. Haemocompatibility tests demonstrated that PEG hydrogel coatings significantly reduced platelet adhesion and prolonged plasma recalcification time. These results suggest that heparin-loaded PEG hydrogels are potential anti-thrombogenic coatings for ECMO.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Heparina , Materiales Biocompatibles/química , Heparina/farmacología , Hidrogeles/química , Hidrogeles/farmacología , Polietilenglicoles/química , Agua
11.
Intensive Care Med Exp ; 10(1): 12, 2022 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-35377109

RESUMEN

BACKGROUND: Fluid resuscitation is the standard treatment to restore circulating blood volume and pressure after massive haemorrhage and shock. Packed red blood cells (PRBC) are transfused to restore haemoglobin levels. Restoration of microcirculatory flow and tissue oxygen delivery is critical for organ and patient survival, but these parameters are infrequently measured. Patient Blood Management is a multidisciplinary approach to manage and conserve a patient's own blood, directing treatment options based on broad clinical assessment beyond haemoglobin alone, for which tissue perfusion and oxygenation could be useful. Our aim was to assess utility of non-invasive tissue-specific measures to compare PRBC transfusion with novel crystalloid treatments for haemorrhagic shock. METHODS: A model of severe haemorrhagic shock was developed in an intensive care setting, with controlled haemorrhage in sheep according to pressure (mean arterial pressure 30-40 mmHg) and oxygen debt (lactate > 4 mM) targets. We compared PRBC transfusion to fluid resuscitation with either PlasmaLyte or a novel crystalloid. Efficacy was assessed according to recovery of haemodynamic parameters and non-invasive measures of sublingual microcirculatory flow, regional tissue oxygen saturation, repayment of oxygen debt (arterial lactate), and a panel of inflammatory and organ function markers. Invasive measurements of tissue perfusion, oxygen tension and lactate levels were performed in brain, kidney, liver, and skeletal muscle. Outcomes were assessed during 4 h treatment and post-mortem, and analysed by one- and two-way ANOVA. RESULTS: Each treatment restored haemodynamic and tissue oxygen delivery parameters equivalently (p > 0.05), despite haemodilution after crystalloid infusion to haemoglobin concentrations below 70 g/L (p < 0.001). Recovery of vital organ-specific perfusion and oxygen tension commenced shortly before non-invasive measures improved. Lactate declined in all tissues and correlated with arterial lactate levels (p < 0.0001). The novel crystalloid supported rapid peripheral vasodilation (p = 0.014) and tended to achieve tissue oxygen delivery targets earlier. PRBC supported earlier renal oxygen delivery (p = 0.012) but delayed peripheral perfusion (p = 0.034). CONCLUSIONS: Crystalloids supported vital organ oxygen delivery after massive haemorrhage, despite haemodilution to < 70 g/L, confirming that restrictive transfusion thresholds are appropriate to support oxygen delivery. Non-invasive tissue perfusion and oximetry technologies merit further clinical appraisal to guide treatment for massive haemorrhage in the context of Patient Blood Management.

12.
Intensive Care Med Exp ; 9(1): 60, 2021 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-34950993

RESUMEN

BACKGROUND: Heart transplantation (HTx) from brainstem dead (BSD) donors is the gold-standard therapy for severe/end-stage cardiac disease, but is limited by a global donor heart shortage. Consequently, innovative solutions to increase donor heart availability and utilisation are rapidly expanding. Clinically relevant preclinical models are essential for evaluating interventions for human translation, yet few exist that accurately mimic all key HTx components, incorporating injuries beginning in the donor, through to the recipient. To enable future assessment of novel perfusion technologies in our research program, we thus aimed to develop a clinically relevant sheep model of HTx following 24 h of donor BSD. METHODS: BSD donors (vs. sham neurological injury, 4/group) were hemodynamically supported and monitored for 24 h, followed by heart preservation with cold static storage. Bicaval orthotopic HTx was performed in matched recipients, who were weaned from cardiopulmonary bypass (CPB), and monitored for 6 h. Donor and recipient blood were assayed for inflammatory and cardiac injury markers, and cardiac function was assessed using echocardiography. Repeated measurements between the two different groups during the study observation period were assessed by mixed ANOVA for repeated measures. RESULTS: Brainstem death caused an immediate catecholaminergic hemodynamic response (mean arterial pressure, p = 0.09), systemic inflammation (IL-6 - p = 0.025, IL-8 - p = 0.002) and cardiac injury (cardiac troponin I, p = 0.048), requiring vasopressor support (vasopressor dependency index, VDI, p = 0.023), with normalisation of biomarkers and physiology over 24 h. All hearts were weaned from CPB and monitored for 6 h post-HTx, except one (sham) recipient that died 2 h post-HTx. Hemodynamic (VDI - p = 0.592, heart rate - p = 0.747) and metabolic (blood lactate, p = 0.546) parameters post-HTx were comparable between groups, despite the observed physiological perturbations that occurred during donor BSD. All p values denote interaction among groups and time in the ANOVA for repeated measures. CONCLUSIONS: We have successfully developed an ovine HTx model following 24 h of donor BSD. After 6 h of critical care management post-HTx, there were no differences between groups, despite evident hemodynamic perturbations, systemic inflammation, and cardiac injury observed during donor BSD. This preclinical model provides a platform for critical assessment of injury development pre- and post-HTx, and novel therapeutic evaluation.

13.
Sci Rep ; 11(1): 20458, 2021 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-34650063

RESUMEN

Refractory cardiogenic shock (CS) often requires veno-arterial extracorporeal membrane oxygenation (VA-ECMO) to sustain end-organ perfusion. Current animal models result in heterogenous cardiac injury and frequent episodes of refractory ventricular fibrillation. Thus, we aimed to develop an innovative, clinically relevant, and titratable model of severe cardiopulmonary failure. Six sheep (60 ± 6 kg) were anaesthetized and mechanically ventilated. VA-ECMO was commenced and CS was induced through intramyocardial injections of ethanol. Then, hypoxemic/hypercapnic pulmonary failure was achieved, through substantial decrease in ventilatory support. Echocardiography was used to compute left ventricular fractional area change (LVFAC) and cardiac Troponin I (cTnI) was quantified. After 5 h, the animals were euthanised and the heart was retrieved for histological evaluations. Ethanol (58 ± 23 mL) successfully induced CS in all animals. cTnI levels increased near 5000-fold. CS was confirmed by a drop in systolic blood pressure to 67 ± 14 mmHg, while lactate increased to 4.7 ± 0.9 mmol/L and LVFAC decreased to 16 ± 7%. Myocardial samples corroborated extensive cellular necrosis and inflammatory infiltrates. In conclusion, we present an innovative ovine model of severe cardiopulmonary failure in animals on VA-ECMO. This model could be essential to further characterize CS and develop future treatments.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Respiratoria/terapia , Choque Cardiogénico/terapia , Animales , Modelos Animales de Enfermedad , Ecocardiografía , Femenino , Miocardio/patología , Ovinos , Choque Cardiogénico/diagnóstico por imagen
14.
Shock ; 56(6): 1080-1091, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34014886

RESUMEN

BACKGROUND: Aggressive fluid or blood component transfusion for severe hemorrhagic shock may restore macrocirculatory parameters, but not always improve microcirculatory perfusion and tissue oxygen delivery. We established an ovine model of hemorrhagic shock to systematically assess tissue oxygen delivery and repayment of oxygen debt; appropriate outcomes to guide Patient Blood Management. METHODS: Female Dorset-cross sheep were anesthetized, intubated, and subjected to comprehensive macrohemodynamic, regional tissue oxygen saturation (StO2), sublingual capillary imaging, and arterial lactate monitoring confirmed by invasive organ-specific microvascular perfusion, oxygen pressure, and lactate/pyruvate levels in brain, kidney, liver, and skeletal muscle. Shock was induced by stepwise withdrawal of venous blood until MAP was 30 mm Hg, mixed venous oxygen saturation (SvO2) < 60%, and arterial lactate >4 mM. Resuscitation with PlasmaLyte® was dosed to achieve MAP > 65 mm Hg. RESULTS: Hemorrhage impacted primary outcomes between baseline and development of shock: MAP 89 ±â€Š5 to 31 ±â€Š5 mm Hg (P < 0.01), SvO2 70 ±â€Š7 to 23 ±â€Š8% (P < 0.05), cerebral regional tissue StO2 77 ±â€Š11 to 65 ±â€Š9% (P < 0.01), peripheral muscle StO2 66 ±â€Š8 to 16 ±â€Š9% (P < 0.01), arterial lactate 1.5 ±â€Š1.0 to 5.1 ±â€Š0.8 mM (P < 0.01), and base excess 1.1 ±â€Š2.2 to -3.6 ±â€Š1.7 mM (P < 0.05). Invasive organ-specific monitoring confirmed reduced tissue oxygen delivery; oxygen tension decreased and lactate increased in all tissues, but moderately in brain. Blood volume replacement with PlasmaLyte® improved primary outcome measures toward baseline, confirmed by organ-specific measures, despite hemoglobin reduced from baseline 10.8 ±â€Š1.2 to 5.9 ±â€Š1.1 g/dL post-resuscitation (P < 0.01). CONCLUSION: Non-invasive measures of tissue oxygen delivery and oxygen debt repayment are suitable outcomes to inform Patient Blood Management of hemorrhagic shock, translatable for pre-clinical assessment of novel resuscitation strategies.


Asunto(s)
Consumo de Oxígeno , Oxígeno/metabolismo , Recuperación de la Función , Resucitación , Choque Hemorrágico/terapia , Animales , Transfusión Sanguínea , Modelos Animales de Enfermedad , Femenino , Humanos , Persona de Mediana Edad , Ovinos
15.
Membranes (Basel) ; 11(5)2021 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-33923070

RESUMEN

In vitro hemolysis testing is commonly used to determine hemocompatibility of ExtraCorporeal Membrane Oxygenation (ECMO). However, poor reproducibility remains a challenging problem, due to several unidentified influencing factors. The present study investigated potential factors, such as flow rates, the use of anticoagulants, and gender of blood donors, which could play a role in hemolysis. Fresh human whole blood was anticoagulated with either citrate (n = 6) or heparin (n = 12; 6 female and 6 male blood donors). Blood was then circulated for 360 min at 4 L/min or 1.5 L/min. Regardless of flow rate conditions, hemolysis remained unchanged over time in citrated blood, but significantly increased after 240 min circulation in heparinized blood (p ≤ 0.01). The ratio of the normalized index of hemolysis (NIH) of heparinized blood to citrated blood was 11.7-fold higher at 4 L/min and 16.5-fold higher at 1.5 L/min. The difference in hemolysis between 1.5 L/min and 4 L/min concurred with findings of previous literature. In addition, the ratio of NIH of male heparinized blood to female was 1.7-fold higher at 4 L/min and 2.2-fold higher at 1.5 L/min. Our preliminary results suggested that the choice of anticoagulant and blood donor gender could be critical factors in hemolysis studies, and should be taken into account to improve testing reliability during ECMO.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...